PV Powered 2500 Installationsanleitung Seite 39

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 52
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 38
SMA Solar Technology AG Troubleshooting
Installation Guide SB25_30-IEN092520 39
3. Place the extractor tool into the openings of the
terminal contacts (1).
The terminal clamps loosen up.
If you do not receive an extractor tool for operating
the terminal clamps with your replacement
varistors, contact SMA Solar Technology. As an
alternative, the terminal contacts can be operated
using a 3.5 mm wide screwdriver.
4. Remove the varistor (2).
5. Insert new varistor.
The pole with the small loop (crimp) must be fitted
to terminal A (3) when remounting.
6. Close the Sunny Boy as described in section 7.2 "Closing the Sunny Boy" (page33).
The check of the varistors is completed.
☑There is no conducting
connection.
The respective varistor is not working and must be
replaced.
Varistor failure is generally due to influences which affect
all varistors similarly (temperature, age, induced
overvoltage). It is therefore recommended that you
replace both varistors.
The varistors are specially manufactured for use in the
Sunny Boy and are not commercially available. They must
be ordered directly from SMA Solar Technology (see
section 12 "Accessories" (page46)).
To replace the varistors, proceed to step 3.
NOTICE!
The Sunny Boy could be irreparably damaged by overvoltage!
If varistors are missing, the Sunny Boy is no longer protected against overvoltages.
Replacement varistors should be obtained as soon as possible.
•Do not operate the Sunny Boy without varistors in systems with a high risk of
overvoltages.
Result Measure
Seitenansicht 38
1 2 ... 34 35 36 37 38 39 40 41 42 43 44 ... 51 52