PV Powered PVP1800 Spezifikationen Seite 17

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 34
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 16
PV Powered LLC 16 11-18-28-704
2.3.e Connecting Communications (Optional Step)
To connect the communications and load the software follow the steps outlined below
(Refer to Figures 18 and 19):
1. Hardwire the communications cable to the communication terminal, or plug in the
D-sub cable to the serial port.
Figure 18: Communications located on the Power Distribution Board
Serial Connection Table
Figure 19: Hardwiring the serial connection
2. Replace the front cover of the StarInverter and tighten the two or four screws
located on the cover.
5 Pin Screw
Terminal
Connector
Serial Cable
Serial Function
1 7 Request to Send (RTS)
2 2 Receive Data (Rx)
3 4 Data Terminal Ready (DTR)
4 3 Transmit Data (Tx)
5 5 Signal Ground (SG)
Seitenansicht 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 33 34

Kommentare zu diesen Handbüchern

Keine Kommentare