Installation
5.7 Connections of the PV power system
5.7.1 Announcements
5.7.2 PV array connection types
Ensure that the DC side is not charged before installation and maintenance.
But after DC side discharge for a period of time, the capacitor is still charged,
so need to wait for 5 minutes to ensure that the capacitors is discharged.
Before the electrical connection, make sure to use opaque material to cover
the PV battery or disconnected the breaker of DC side. Exposure to the sun, PV
array will produce a dangerous voltage.
PV array connection types: There are 2 independent MPP trackers in inverter. You can choose common
-string input connection and multi-strings input connection. We recommend that choose multi-strings
to harvest max. PV power.
Please select excellent function and reliable quality PV arrays. Open-circuit voltage of PV arrays should
be<Max. input DC input voltage. Operating voltage should be conformed to MPPT voltage range.
Table 2 DC Voltage Limitation
Model
MPPT voltage range
Max. DC voltage
SolarRiver
3400TL-D
SolarRiver
4000TL-D
SolarRiver
4500TL-D
SolarRiver
5000TL-D
SolarRiver
5200TL-D
160~500V 160~500V
550 Vdc
165~500V 175~500V175~500V
Figure 10 Multi-string input connection (Left) and common-string input connection (Right)]