Ground fault protection
Grid monitoring
Ground fault current
monitoring
DC injection monitoring
Yes
Yes
Yes
Yes
Continued:
4.4 General Data
Model
Dimensions (W/H/D)
[mm]
Weight [kg]
Operating temperature
range [℃]
Topology
Degree of protection
IP65
Internal consumption
(night) [W]
Cooling concept
Noise (typical) [dB]
LCD display
Communication interfaces
Standard warranty [year]
SolarRiver
1100TL
SolarRiver
1600TL
SolarRiver
2300TL
SolarRiver
3000TL
SolarRiver
3300TL
SolarRiver
4400TL
SolarRiver
5200TL
285 / 385 / 145 328 / 450 / 161 347 / 443 / 180
11.4 11.4
Convection Fan
17.5 17.9 18.9 19.2 19.4
<28 <28
RS232 RS232 RS485 / RS232
<30
0
-20 °C ~ +60 (derating at 45 °C)
Backlight, 16*2 character LCD
Transformerless
5 years
<30 <30
SolarRiver
3680TL
19.2
<40 <40
<40
Bild 3 SolarLake Anschlussklemmen des Wechselrichters
5 Function
Operation Mode
【Stand-by Mode】
The standby mode means that the inverter is ready for operation but still not connected to the grid. In this
mode, it will continue to check whether PV array has enough power to feedback into grid. When the
inverter passes dump load test after startup, it will change from standby mode to Checking mode.
【Checking Mode】
If inverter passes dump load test and no error/fault occurs, will start checking mode to deliver power.
【On-grid Mode】
In this mode, SolarRiver series inverters convert PV array’s DC into AC and feedback into grid.
Caution!
It is normal that the inverter decreases the output power in the condition of
thermal protection, but if this occurs frequently the heat sink and the fan will
need to be checked and the inverter may need to be shifted to a place with
better air flow. If the fan is dirty it should be cleaned and if the output power
decrease is caused by electricity issues, please ask for professional support.
10
Technical Data & Function