17
Installation
Figure 14 AC Connector details
SolarRiver 2300TL~5200TL SolarRiver 1100TL~1600TL
Socket element
Thread sleeve
with sealing ring
10-14mm
sealing ring 6-10mm
Pressure screw
Follow following steps for wiring AC Connectors.
Step1: Pass the AC wire through the threaded sleeve and pressure screw (See figure 15).
Step2 : Connect the AC cables as explained below.
• Fix the green and yellow ground cable to the ground terminator in the AC Connector (Figure 16).
• Fix the blue Neutral cable to the N(Neutral) terminator in the AC Connector.
• Fix the Line cable (brown or black wire) to the L(Line) terminator in the AC Connector.
Figure 15
Figure 16 AC Connector
Thread sleeve
Pressure screw