8 Diagnosis and maintenance
Operating state
Associatedinuencing
factors
Grid feed-in
Normal operation
No factors are present that limit
the energy production results.
Yes
Limited operation
Non-critical factors that can
affect the energy production but
which are not equipment or sys-
tem failures (e.g., self-test).
Limited
Warning
External events or internal
failures are present that affect
the production results.
Yes
Failure No
Insulation or
grounding failure
A problem exists with the
insulation
No
See section 8.1.2 for a description of the inuencing factors.
Note: When in failure mode, the inverter will not produce power.
Different inuencing factors are assigned to the individual operating states. These inuencing
factors are divided into the following categories.
Non-critical factors
Non-critical factors are (for example) the self-test or a DC voltage that is too low due to bad wea-
ther. Non-critical factors are therefore not failures.
Events
Events are usually caused outside the inverter. Events are divided into external events (e.g., vol-
tage or frequency errors) and parameter changes occurring via the keys or the RS-485 interface.
Internal failures
Internal failures are caused from within the inverter and must be corrected with help of the Solect-
ria Support Team.
8.1 Operating states
8.1.1 Types of operating states
8.1.2 Factorsinuencingtheoperatingstate
Congurableparameters
Display text Designation Description
Menu number
Menu number Any valid menu number.